戴安CRD200suppressors离子色谱抑制器厂家
货号 062986
完整参数 ▼
适用于 Dionex Reagent-Free 离子色谱 (RFIC) 系统
操作 通过碳酸选择性透气膜壁扩散法去除抑制型淋洗液中的二氧化碳。
类型 去碳酸装置
孔隙体积 80 μL
描述 2 mm CRD 200
Unit Size Each 1
货号 062983
完整参数 ▼
适用于 Dionex 免试剂离子色谱 (RFIC) 系统
操作 通过碳酸盐选择性透气膜壁扩散法去除抑制后淋洗液中的二氧化碳。
类型 去碳酸盐装置
孔隙体积 225 μL
描述 4 mm CRD 200
Unit Size Each 1
货号 064637
完整参数 ▼
适用于 Dionex 免试剂离子色谱 (RFIC) 系统
操作 通过碳酸盐选择性透气膜扩散法去除抑制型淋洗液流中的二氧化碳。
类型 碳酸盐去除装置
孔隙体积 225 μL
描述 4 mm CRD 300
Unit Size Each 1
戴安CRD200suppressors离子色谱抑制器厂家
检硕科学器材(上海)有限公司是一家专注于分析检测行业的系统性供应商,一直致力于分析测试技术方面进口仪器的配件耗材供应,主要优势经销代理品牌:美国赛默飞世尔(ThermoFisher)原装配件耗材(比如:ICP光谱,ICP-MS质谱,AAS原子吸收光谱, GC-MS气质,LC-MS液质,ARL直读光谱ARL3460,ARL4460,ARLiSpark8820/8860/8880),9800/9900X荧光光谱,同位素质谱,红外光谱等仪器备件),珀金埃尔默(PerkinElmer)耗材,美国安捷伦(Agilent)耗材,美国沃特世(Waters)耗材,戴安(DIONEX)色谱耗材,岛津(SHIMADZU)耗材,瑞士万通(Metrohm),CEM耗材等。
Plumbed between the suppressor and detector cell, carbonate transfer is aided by a countercurrent flow of basic solution.
Dionex CRD 300 Carbonate Removal Device
Designed for use with carbonate eluent-based chemistries using Thermo Scientific
Dionex
IC columns
Removes carbonic acid from the suppressed carbonate eluent
Provides a detection system that is similar to systems using hydroxide eluents
Reduces the baseline for higher sensitivity
Increases linearity range
Available in two formats:
Dionex CRD 300 (4mm) for standard bore systems
Dionex CRD 300 (2mm) for microbore systems
Dionex CRD 300 can be installed in any Dionex IC system running carbonate as an eluent with a Dionex AERS 500 suppressor. The device requires either a constant flow of basic solution from a peristaltic pump or evacuation by a vacuum pump. See Dionex CRD Carbonate Removal Device Accessories for peristaltic pump and tubing. The Dionex CRD requires no reagents or software control.
Dionex CRD 180 and 200 Carbonate Removal Devices
The Dionex CRD 180 and 200 device enhances IC signals by continuously removing carbon dioxide from the sample on any Dionex
Reagent-Free
IC (RFIC
) system using hydr[oxide eluent.
Designed for use with hydroxide- and borate-based chemistries using Thermo Scientific
Dionex
IC columns
Removes the carbonate introduced from samples with high levels of dissolved carbon dioxide
Improves integration and quantitation of some analyte peaks that elute close to carbonate, such as such as sulfate
Available in several formats:
Dionex CRD 200 (4mm) for standard bore systems, including standard bore columns packed with 4μm resin
Dionex CRD 200 (2mm) for microbore systems, including microbore columns packed with 4μm resin
Dionex CRD 200 (Capillary) for capillary-scale systems (0.4mm columns) using flow rates of 5–30μL/min
Dionex CRD 180 (Capillary) is a version of the Dionex CRD 200 that has reduced internal volume and supports carbonate removal from 0.25mm and 0.4mm capillary columns
The Dionex CRD 180 and 200 device is easily installed in any Dionex RFIC system equipped with an eluent generator; a Thermo Scientific
Dionex
CR-ATC Continuously Regenerated Anion Trap Column; and a Thermo Scientific
Dionex
AERS
500 Anion Electrolytically Regenerated Suppressor or Dionex
ACES
300 Anion Capillary Electrolytic Suppressor.